Acme Panel-Tran Zone Power Center Transformers
Acme’s
Panel-Tran® Power Center is a pre-wired combination of a primary breaker
disconnect, dry-type shielded transformer, secondary breaker disconnect
and a secondary power panel all in one convenient package. You save
time, space and money by not having to individually assemble, mount and
wire these components. Simply add the breakers of your choice and you’re
ready to go.
FEATURES
■ 600 volt class and below
■ Single and three phase, 480 and 600 volt primary, 60 Hz
■ Primary and secondary main circuit breakers provided
■ UL-3R enclosure
■ 5 through 25 KVA single phase, 9 through 30 KVA
three phase
■ Meets or exceeds UL, CSA, NEMA, ANSI and
OSHA Standards
■ UL Listed and CSA Certified
■ Ten-year limited warranty
■ Shielded for cleaner power
■ Available in 304 stainless steel
304 STAINLESS STEEL PANEL-TRAN®
FEATURES
■ 3R Enclosure.
■ Abundant knockouts provided.
■ Comply with NEC Class 1, Division 2,
Group A-D when installed per NEC 501-2 (b).
■ Encapsulated construction.
■ Single phase: 5 – 25 KVA.
Three phase: 9 – 30 KVA.
APPLICATIONS
■ Harsh industrial locations
■ Corrosive chemical exposure
■ Waste water treatment facilities
■ Coastal or marine applications with high salt spray level
■ Any application where painted cold roll steel is not adequate
ELECTRICAL
CHARACTERISTICS
SINGLE PHASE
Primary Voltage:
480 Volts; 600 Volts Single Phase, 60 Hz 2 — 5% BNFC taps
Secondary Voltage:
240/120 Volts Single Phase, 60 Hz Three wire system
KVA’s Available: 5, 7.5, 10, 15 and 25 KVA
THREE PHASE
Primary Voltage: 480 Volts Delta; 600 Volts Delta Three Phase, 60
Hz With 2 — 5% BNFC taps
Secondary Voltage: 208Y/120 Volts Three Phase, 60 Hz Four wire
system
KVA’s Available:
9, 15, 22.5 and 30 KVA
Insulation Class:
180°C, U.L. recognized system, 115°C rise Regulation: 2 — 3% at unity
power factor
UL-3R Enclosures All Panel-Tran® enclosures are UL-3R listed for
indoor and outdoor use.
Transformer Assembly Acme totally encapsulated distribution
transformers are designed for general purpose
indoor/outdoor operation. Panel-Tran® can be installed in a wide variety
of atmospheric and environmental conditions. A 180°C, U.L. recognized
insulation system is used. Panel-Tran® units are electrostatically
shielded to provide transient voltage protection at no extra cost.
Panel Assembly The power panel assembly will accommodate
one-inch, 1, 2 or 3-pole, common trip, duplex
secondary branch circuit breakers and ground fault circuit breakers. Per
UL and NEC requirements, the Panel-Tran® assembly comes fully equipped
with primary and secondary main circuit breakers. Branch circuit
breakers should be obtained from our local distributor once you have
established your branch circuit requirements.
Panel-Tran®—Why? Panel-Tran® eliminates the normal tangled masses
of secondary circuit feeders and gives your industrial/commercial
distribution systems new flexibility. Use your high voltage bus to full
advantage by putting power where the problem is. Reduce cost — save
space — keep flexible.
Panel-Tran®—Where? Anywhere 120, 208 or 240 volt branch circuits
are required. Typically, Panel-Tran® is best applied in situations
similar to the following: Powering foreman centers, vending machine
areas, factory test set- ups, office buildings, mining applications,
assembly lines, portable or temporary power sources, parking lots, small
machine set-ups, light industrial areas, warehouses, and numerous other
locations. Use where your branch circuits may require future change or
expansion.
UL Listed Panel-Tran® has been listed by Underwriters’
Laboratories for both indoor and outdoor operation under their unit
substation classification, file number E-56936. In addition, Panel-Tran®
is U.L. listed as suitable for use as Service Entrance Equipment.
Meets The NEC Panel-Tran® fully complies with Article 450-3 of
the latest edition of the NEC.
Protection A primary main breaker protects the transformer and
acts as a disconnect device. This primary main breaker has a high
interrupting capacity to handle fault conditions. A secondary main
breaker, between the transformer and the panel, is required by the N.E.C.
Branch Circuits Typical 1" snap in circuit breakers, regular or
duplex, must be field installed. They are not provided with the
Panel-Tran® unit. A secondary ground is provided within the wiring
compartment for accepting your branch unit. All of the breakers,
including the primary main, secondary main, and branch circuit breakers
are located in the lower section of the Panel-Tran®. This lower section
is protected by a hinged, removable front cover which can be padlocked
for safety.
Recommended Branch Breakers We suggest using branch breakers of
the same manufacture as the panel in
Panel-Tran®. Please contact the factory for the proper branch breaker
recommendation.
Connections All Panel-Tran® connections will accept copper or
aluminum conductor.
SELECTION CHARTS
GROUP I
480 PRIMARY VOLTS-240/120 SECONDARY VOLTS-10, 60Hz
| KVA |
CATALOG NO. |
| 5.0 |
PT-06-1150005-LS |
| 7.5 |
PT-06-1150007-LS |
| 10.0 |
PT-06-1150010-LS |
| 15.0 |
PT-06-1150015-LS |
| 25.0 |
PT-06-1150025-LS |
GROUP I-304 SS
480 PRIMARY VOLTS-240/120 SECONDARY VOLTS-10, 60Hz
| KVA |
CATALOG NO. |
| 5.0 |
PT06-1150005-LS |
| 7.5 |
PT06-1150007-LS |
| 10.0 |
PT06-1150010-LS |
| 15.0 |
PT06-1150015-LS |
| 25.0 |
PT06-1150025-LS |
GROUP A
480 PRIMARY VOLTS-208Y/120 SECONDARY VOLTS-30, 60Hz
| KVA |
CATALOG NO. |
| 9.0 |
PTBA-3150009-LS |
| 15.0 |
PTBA-3150015-LS |
| 22.5 |
PTBA-3150022-LS |
| 30.0 |
PTBA-3150030-LS |
GROUP A-304SS
480 PRIMARY VOLTS-208Y/120 SECONDARY VOLTS-30, 60Hz
| KVA |
CATALOG NO. |
| 9.0 |
PTBA-3150009-SS |
| 15.0 |
PTBA-3150015-SS |
| 22.5 |
PTBA-3150022-SS |
| 30.0 |
PTBA-3150030-SS |