Power Transformer Home

Power Transformer Co.   
The Power Transformer Resource     

transformer guide
Small kVA 3 Phase Transformers Guide



Hammond Drive Isolation Transformers

To Order Hammond Transformers We Recommend TEMCo
Ph: 1-800-613-2290
Or 1-510-490-2187
Link: Hammond Drive Isolation Transformer
Link: Drive Isolation Transformer

Hammond Drive Isolation TransformerWith today's technological advances in solid-state power control devices, the use of AC and DC variable speed drives has proliferated in many industrial markets. General purpose distribution transformers are not adequate for this type of application. Hammond's Drive Isolation transformers are designed to meet the rugged demands of both AC and DC variable speed drives and also to provide the required voltage change. The separate primary and secondary windings provide electrical isolation between the incoming line and the SCR load. The windings are designed to withstand overcurrent of 150% of the rated load for 60 seconds or 200% of the rated load for 30 seconds. A duty cycle of one start for every two hours is permitted. Drive Isolation Transformers are sized to match standard motor horsepower and voltage ratings. Standard sizes range from 5 to 600 HP in six standard voltages in both aluminum and copper. Nonstandard sizes and voltages are available upon request.

Selection Charts

ALUMINUM WOUND, THREE PHASE

208 Primary Volts 480 Secondary Volts-60 Hz

KVA CATALOG NO.
7.5 DM007BK
11.0 DM011BK
14.0 DM014BK
20.0 DM020BK
27.0 DM027BK
34.0 DM034BK
40.0 DM040BK
51.0 DM051BK
63.0 DM063BK
75.0 DM075BK
93.0 DM093BK
118.0 DM118BK
145.0 DM145BK
175.0 DM175BK
220.0 DM220BK
275.0 DM275BK
330.0 DM330BK
440.0 DM440BK
550.0 DM550BK
660.0 DM660BK

230 Primary Volts 230 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DM007CC
11.0 DM011CC
14.0 DM014CC
20.0 DM020CC
27.0 DM027CC
34.0 DM034CC
40.0 DM040CC
51.0 DM051CC
63.0 DM063CC
75.0 DM075CC
93.0 DM093CC
118.0 DM118CC
145.0 DM145CC
175.0 DM175CC
220.0 DM220CC
275.0 DM275CC
330.0 DM330CC
440.0 DM440CC
550.0 DM550CC
660.0 DM660CC

460 Primary Volts 230 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DM007JC
11.0 DM011JC
14.0 DM014JC
20.0 DM020JC
27.0 DM027JC
34.0 DM034JC
40.0 DM040JC
51.0 DM051JC
63.0 DM063JC
75.0 DM075JC
93.0 DM093JC
118.0 DM118JC
145.0 DM145JC
175.0 DM175JC
220.0 DM220JC
275.0 DM275JC
330.0 DM330JC
440.0 DM440JC
550.0 DM550JC
660.0 DM660JC

460 Primary Volts 400 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DM007JH
11.0 DM011JH
14.0 DM014JH
20.0 DM020JH
27.0 DM027JH
34.0 DM034JH
40.0 DM040JH
51.0 DM051JH
63.0 DM063JH
75.0 DM075JH
93.0 DM093JH
118.0 DM118JH
145.0 DM145JH
175.0 DM175JH
220.0 DM220JH
275.0 DM275JH
330.0 DM330JH
440.0 DM440JH
550.0 DM550JH
660.0 DM660JH

460 Primary Volts 460 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DM007JJ
11.0 DM011JJ
14.0 DM014JJ
20.0 DM020JJ
27.0 DM027JJ
34.0 DM034JJ
40.0 DM040JJ
51.0 DM051JJ
63.0 DM063JJ
75.0 DM075JJ
93.0 DM093JJ
118.0 DM118JJ
145.0 DM145JJ
175.0 DM175JJ
220.0 DM220JJ
275.0 DM275JJ
330.0 DM330JJ
440.0 DM440JJ
550.0 DM550JJ
660.0 DM660JJ

480 Primary Volts 240 Secondary Volts-60Hz
 

KVA CATALOG NO.
7.5 DM007KM
11.0 DM011KM
14.0 DM014KM
20.0 DM020KM
27.0 DM027KM
34.0 DM034KM
40.0 DM040KM
51.0 DM051KM
63.0 DM063KM
75.0 DM075KM
93.0 DM093KM
118.0 DM118KM
145.0 DM145KM
175.0 DM175KM
220.0 DM220KM
275.0 DM275KM
330.0 DM330KM
440.0 DM440KM
550.0 DM550KM
660.0 DM660KM


 

480 Primary Volts 480 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DM007KK
11.0 DM011KK
14.0 DM014KK
20.0 DM020KK
27.0 DM027KK
34.0 DM034KK
40.0 DM040KK
51.0 DM051KK
63.0 DM063KK
75.0 DM075KK
93.0 DM093KK
118.0 DM118KK
145.0 DM145KK
175.0 DM175KK
220.0 DM220KK
275.0 DM275KK
330.0 DM330KK
440.0 DM440KK
550.0 DM550KK
660.0 DM660KK

575 Primary Volts 460 Secondary Volts-60Hz
 

KVA CATALOG NO.
7.5 DM007NJ
11.0 DM011NJ
14.0 DM014NJ
20.0 DM020NJ
27.0 DM027NJ
34.0 DM034NJ
40.0 DM040NJ
51.0 DM051NJ
63.0 DM063NJ
75.0 DM075NJ
93.0 DM093NJ
118.0 DM118NJ
145.0 DM145NJ
175.0 DM175NJ
220.0 DM220NJ
275.0 DM275NJ
330.0 DM330NJ
440.0 DM440NJ
550.0 DM550NJ
660.0 DM660NJ

575 Primary Volts 575 Secondary Volts-60Hz
 

KVA CATALOG NO.
7.5 DM007NN
11.0 DM011NN
14.0 DM014NN
20.0 DM020NN
27.0 DM027NN
34.0 DM034NN
40.0 DM040NN
51.0 DM051NN
63.0 DM063NN
75.0 DM075NN
93.0 DM093NN
118.0 DM118NN
145.0 DM145NN
175.0 DM175NN
220.0 DM220NN
275.0 DM275NN
330.0 DM330NN
440.0 DM440NN
550.0 DM550NN
660.0 DM660NN

 

COPPER WOUND, THREE PHASE

208 Primary Volts 480 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DM007BKCN
11.0 DM011BKCN
14.0 DM014BKCN
20.0 DM020BKC
27.0 DM027BKC
34.0 DM034BKC
40.0 DM040BKC
51.0 DM051BKC
63.0 DM063BKC
75.0 DM075BKC
93.0 DM093BKC
118.0 DM118BKC
145.0 DM145BKC
175.0 DM175BKC
220.0 DM220BKC
275.0 DM275BKC
330.0 DM330BKC
440.0 DM440BKC
550.0 DM550BKC
660.0 DM660BKC

460 Primary Volts 400 Secondary Volts-60Hz
 

KVA CATALOG NO.
7.5 DM007JHCN
11.0 DM011JHCN
14.0 DM014JHCN
20.0 DM020JHCN
27.0 DM027JHCN
34.0 DM034JHC
40.0 DM040JHC
51.0 DM051JHC
63.0 DM063JHC
75.0 DM075JHC
93.0 DM093JHC
118.0 DM118JHC
145.0 DM145JHC
175.0 DM175JHC
220.0 DM220JHC
275.0 DM275BJH
330.0 DM330JHC
440.0 DM440JHC
550.0 DM550JHC
660.0 DM660JHC

460 Primary Volts 460 Secondary Volts-60Hz

480 Primary Volts 240 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DM007KDCN
11.0 DM011KDCN
14.0 DM014KDCN
20.0 DM020KDCN
27.0 DM027KDCN
34.0 DM034KDCN
40.0 DM040KDC
51.0 DM051KDC
63.0 DM063KDC
75.0 DM075KDC
93.0 DM093KDC
118.0 DM118KDC
145.0 DM145KDC
175.0 DM175KDC
220.0 DM220KDC
275.0 DM275KDC
330.0 DM330KDC
440.0 DM440KDC
550.0 DM550KDC
660.0 DM660KDC

480 Primary Volts 480 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DM007KKCN
11.0 DM011KKCN
14.0 DM014KKCN
20.0 DM020KKCN
27.0 DM027KKCN
34.0 DM034KKCN
40.0 DM040KKC
51.0 DM051KKC
63.0 DM063KKC
75.0 DM075KKC
93.0 DM093KKC
118.0 DM118KKC
145.0 DM145KKC
175.0 DM175KKC
220.0 DM220KKC
275.0 DM275KKC
330.0 DM330KKC
440.0 DM440KKC
550.0 DM550KKC
660.0 DM660KKC

575 Primary Volts 460 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DM007NJCN
11.0 DM011NJCN
14.0 DM014NJCN
20.0 DM020NJCN
27.0 DM027NJCN
34.0 DM034NKCN
40.0 DM040NJCN
51.0 DM051NJC
63.0 DM063NJC
75.0 DM075NJC
93.0 DM093NJC
118.0 DM118NJC
145.0 DM145NJC
175.0 DM175NJC
220.0 DM220NJC
275.0 DM275NJC
330.0 DM330NJC
440.0 DM440NJC
550.0 DM550NJC
660.0 DM660NJC

575 Primary Volts 575 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DM007NNCN
11.0 DM011NNCN
14.0 DM014NNCN
20.0 DM020NNCN
27.0 DM027NNCN
34.0 DM034NNCN
40.0 DM040NNCN
51.0 DM051NNC
63.0 DM063NNC
75.0 DM075NNC
93.0 DM093NNC
118.0 DM118NNC
145.0 DM145NNC
175.0 DM175NNC
220.0 DM220NNC
275.0 DM275NNC
330.0 DM330NNC
440.0 DM440NNC
550.0 DM550NNC
660.0 DM660NNC


HPS Tribune
Energy Efficient (C802.2) Drive Isolation Transformers

ALUMINUM AND COPPER WOUND FEATURES

SELECTION CHARTS

ALUMINUM WOUND, THREE PHASE

208 Primary Volts 480 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007BK
11.0 DE011BK
14.0 DE014BK
20.0 DE020BK
27.0 DE027BK
34.0 DE034BK
40.0 DE040BK
51.0 DE051BK
63.0 DE063BK
75.0 DE075BK
93.0 DE093BK
118.0 DE118BK
145.0 DE145BK
175.0 DE175BK
220.0 DE220BK
275.0 DE275BK
330.0 DE330BK
440.0 DE440BK
550.0 DE550BK
660.0 DE660BK

230 Primary Volts 230 Secondary Volts-60Hz 

KVA CATALOG NO.
7.5 DE007CC
11.0 DE011CC
14.0 DE014CC
20.0 DE020CC
27.0 DE027CC
34.0 DE034CC
40.0 DE040CC
51.0 DE051CC
63.0 DE063CC
75.0 DE075CC
93.0 DE093CC
118.0 DE118CC
145.0 DE145CC
175.0 DE175CC
220.0 DE220CC
275.0 DE275CC
330.0 DE330CC
440.0 DE440CC
550.0 DE550CC
660.0 DE660CC

260 Primary Volts 230 Secondary Volts-60Hz
 

KVA CATALOG NO.
7.5 DE007JC
11.0 DE011JC
14.0 DE014JC
20.0 DE020JC
27.0 DE027JC
34.0 DE034JC
40.0 DE040JC
51.0 DE051JC
63.0 DE063JC
75.0 DE075JC
93.0 DE093JC
118.0 DE118JC
145.0 DE145JC
175.0 DE175JC
220.0 DE220JC
275.0 DE275JC
330.0 DE330JC
440.0 DE440JC
550.0 DE550JC
660.0 DE660JC

 460 Primary Volts 400 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007JH
11.0 DE011JH
14.0 DE014JH
20.0 DE020JH
27.0 DE027JH
34.0 DE034JH
40.0 DE040JH
51.0 DE051JH
63.0 DE063JH
75.0 DE075JH
93.0 DE093JH
118.0 DE118JH
145.0 DE145JH
175.0 DE175JH
220.0 DE220JH
275.0 DE275JH
330.0 DE330JH
440.0 DE440JH
550.0 DE550JH
660.0 DE660JH

 460 Primary Volts 46000 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007JJ
11.0 DE011JJ
14.0 DE014JJ
20.0 DE020JJ
27.0 DE027JJ
34.0 DE034JJ
40.0 DE040JJ
51.0 DE051JJ
63.0 DE063JJ
75.0 DE075JJ
93.0 DE093JJ
118.0 DE118JJ
145.0 DE145JJ
175.0 DE175JJ
220.0 DE220JJ
275.0 DE275JJ
330.0 DE330JJ
440.0 DE440JH
550.0 DE550JJ
660.0 DE660JJ

480 Primary Volts 240 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007KD
11.0 DE011KD
14.0 DE014KD
20.0 DE020KD
27.0 DE027KD
34.0 DE034KD
40.0 DE040KD
51.0 DE051KD
63.0 DE063KD
75.0 DE075KD
93.0 DE093KD
118.0 DE118KD
145.0 DE145KD
175.0 DE175KD
220.0 DE220KD
275.0 DE275KD
330.0 DE330KD
440.0 DE440KD
550.0 DE550KD
660.0 DE660KD

480 Primary Volts 480 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007KK
11.0 DE011KK
14.0 DE014KK
20.0 DE020KK
27.0 DE027KK
34.0 DE034KK
40.0 DE040KK
51.0 DE051KK
63.0 DE063KK
75.0 DE075KK
93.0 DE093KK
118.0 DE118KK
145.0 DE145KK
175.0 DE175KK
220.0 DE220KK
275.0 DE275KK
330.0 DE330KK
440.0 DE440KK
550.0 DE550KK
660.0 DE660KK

575 Primary Volts 460 Secondary Volts-60Hz
 

KVA CATALOG NO.
7.5 DE007NJ
11.0 DE011NJ
14.0 DE014NJ
20.0 DE020NJ
27.0 DE027NJ
34.0 DE034NJ
40.0 DE040NJ
51.0 DE051NJ
63.0 DE063NJ
75.0 DE075NJ
93.0 DE093NJ
118.0 DE118NJ
145.0 DE145NJ
175.0 DE175NJ
220.0 DE220NJ
275.0 DE275NJ
330.0 DE330NJ
440.0 DE440NJ
550.0 DE550NJ
660.0 DE660NJ

575 Primary Volts 575 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007NN
11.0 DE011NN
14.0 DE014NN
20.0 DE020NN
27.0 DE027NN
34.0 DE034NN
40.0 DE040NN
51.0 DE051NN
63.0 DE063NN
75.0 DE075NN
93.0 DE093NN
118.0 DE118NN
145.0 DE145NN
175.0 DE175NN
220.0 DE220NN
275.0 DE275NN
330.0 DE330NN
440.0 DE440NN
550.0 DE550NN
660.0 DE660NN

 

COPPER WOUND, THREE PHASE

 

208 Primary Volts 480 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007BKCN
11.0 DE011BKCN
14.0 DE014BKCN
20.0 DE020BKC
27.0 DE027BKC
34.0 DE034BKC
40.0 DE040BKC
51.0 DE051BKC
63.0 DE063BKC
75.0 DE075BKC
93.0 DE093BKC
118.0 DE118BKC
145.0 DE145BKC
175.0 DE175BKC
220.0 DE220BKC
275.0 DE275BKC
330.0 DE330BKC
440.0 DE440BKC
550.0 DE550BKC
660.0 DE660BKC


230 Primary Volts 230 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007CCCN
11.0 DE011CCCN
14.0 DE014CCCN
20.0 DE020CCC
27.0 DE027CCC
34.0 DE034BCC
40.0 DE040CCC
51.0 DE051CCC
63.0 DE063CCC
75.0 DE075CCC
93.0 DE093CCC
118.0 DE118CCC
145.0 DE145CCC
175.0 DE175CCC
220.0 DE220CCC
275.0 DE275CCC
330.0 DE330CCC
440.0 DE440CCC
550.0 DE550CCC
660.0 DE660CCC

460 Primary Volts 230 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007JCCN
11.0 DE011JCCN
14.0 DE014JCCN
20.0 DE020JCCN
27.0 DE027JCCN
34.0 DE034JCC
40.0 DE040JCC
51.0 DE051JCC
63.0 DE063JCC
75.0 DE075JCC
93.0 DE093JCC
118.0 DE118JCC
145.0 DE145JCC
175.0 DE175JCC
220.0 DE220JCC
275.0 DE275JCC
330.0 DE330JCC
440.0 DE440JCC
550.0 DE550JCC
660.0 DE660JCC

460 Primary Volts 400 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007JHCN
11.0 DE011JHCN
14.0 DE014JHCN
20.0 DE020JHCN
27.0 DE027JHCN
34.0 DE034JHC
40.0 DE040JHC
51.0 DE051JHC
63.0 DE063JHC
75.0 DE075JHC
93.0 DE093JHC
118.0 DE118JHC
145.0 DE145JHC
175.0 DE175JHC
220.0 DE220JHC
275.0 DE275JHC
330.0 DE330JHC
440.0 DE440JHC
550.0 DE550JHC
660.0 DE660JHC

460 Primary Volts 460 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007JJCN
11.0 DE011JJCN
14.0 DE014JJCN
20.0 DE020JJCN
27.0 DE027JJCN
34.0 DE034JJC
40.0 DE040JJC
51.0 DE051JJC
63.0 DE063JJC
75.0 DE075JJC
93.0 DE093JJC
118.0 DE118JJC
145.0 DE145JJC
175.0 DE175JJC
220.0 DE220JJC
275.0 DE275JJC
330.0 DE330JJC
440.0 DE440JJC
550.0 DE550JJC
660.0 DE660JJC

480 Primary Volts 240 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007KDCN
11.0 DE011KDCN
14.0 DE014KDCN
20.0 DE020KDCN
27.0 DE027KDCN
34.0 DE034KDCN
40.0 DE040KDC
51.0 DE051KDC
63.0 DE063KDC
75.0 DE075KDC
93.0 DE093KDC
118.0 DE118KDC
145.0 DE145KDC
175.0 DE175KDC
220.0 DE220KDC
275.0 DE275KDC
330.0 DE330KDC
440.0 DE440KDC
550.0 DE550KDC
660.0 DE660KDC

480 Primary Volts 480 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007KKCN
11.0 DE011KKCN
14.0 DE014KKCN
20.0 DE020KKCN
27.0 DE027KKCN
34.0 DE034KKCN
40.0 DE040KKC
51.0 DE051KKC
63.0 DE063KKC
75.0 DE075KKC
93.0 DE093KKC
118.0 DE118KKC
145.0 DE145KKC
175.0 DE175KKC
220.0 DE220KKC
275.0 DE275KKC
330.0 DE330KKC
440.0 DE440KKC
550.0 DE550KKC
660.0 DE660KKC

575 Primary Volts 460 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007NJCN
11.0 DE011NJCN
14.0 DE014NJCN
20.0 DE020NJCN
27.0 DE027NJCN
34.0 DE034NJCN
40.0 DE040NJCN
51.0 DE051NJC
63.0 DE063NJC
75.0 DE075NJC
93.0 DE093NJC
118.0 DE118NJC
145.0 DE145NJC
175.0 DE175NJC
220.0 DE220NJC
275.0 DE275NJC
330.0 DE330NJC
440.0 DE440NJC
550.0 DE550NJC
660.0 DE660NJC

575 Primary Volts 575 Secondary Volts-60Hz

KVA CATALOG NO.
7.5 DE007NNCN
11.0 DE011NNCN
14.0 DE014NNCN
20.0 DE020NNCN
27.0 DE027NNCN
34.0 DE034NNCN
40.0 DE040NNCN
51.0 DE051NNC
63.0 DE063NNC
75.0 DE075NNC
93.0 DE093NNC
118.0 DE118NNC
145.0 DE145NNC
175.0 DE175NNC
220.0 DE220NNC
275.0 DE275NNC
330.0 DE330NNC
440.0 DE440NNC
550.0 DE550NNC
660.0 DE660NNC

 

o     HAMMOND INDUSTRIAL CONTROL TRANSFORMERS

o     HAMMOND  BUCK BOOST TRANSFORMERS

o     HAMMOND   LINE REACTOR TRANSFORMERS

o     HAMMOND DRIVE ISOLATION TRANSFORMERS

o     HAMMOND MOTOR STARTING AUTO TRANSFORMERS

o     HAMMOND LOW VOLTAGE LIGHTING TRANSFORMERS

o     HAMMOND GENERAL PURPOSE DISTRIBUTION TRANSFORMERS

o     HAMMOND K-FACTOR TRANSFORMERS

o     HAMMOND ENCAPSULATED TRANSFORMERS

o     HAMMOND  AUTOTRANSFORMERS

o     HAMMOND GENERAL PURPOSE MEDIUM VOLTAGE TRANSFORMERS

 

 

 
 Power Transformer Information:

Power Transformer HomeContact Power Transformer Co.


Power Transformer Types

Step Up and Step Down Transformers Step Up and Step Down Transformers to Power transformers to step-up ( raise) or step-down (lower) the electrical voltage.
 
Isolation Transformers Isolation Transformers allows signal or power to be taken from one device and fed into another without electrically connecting the two.
 
Toroidal Transformers Toroidal Transformers are devices that transfer electrical energy from one electric circuit to another, without changing the frequency, by electromagnetic induction.
 
Custom Transformers
 
Custom Transformers are designed to meet certain performance specifications and size requirement that you require. There is a wide range of custom transformer types.
 
Buck Boost Transformers
 
Buck Boost Transformers is a ideal solution for changing line voltage by small amounts. Often used to buck (lower), or boost (raise) the voltage from 208v to 240v for lighting applications.
 
Pole Mounted Transformers
 
Pole Mounted Transformers are mounted to poles for overhead electrical lines. Used in various applications. Are available in single phase or three phase transformers.
 
Medium Voltage Transformers
 
Medium Voltage Transformers are used with a medium range of voltages. They come in a full range from liquid-filled, convention dry type as well as cast coil.
 
Pad Mounted Transformers Pad Mounted Transformers are a excellent choice for commercial and industrial such as manufacturing facilities, refineries, office buildings, schools, hospitals, restaurants, and retail stores. They come in various sizes and can be used underground as well.
 
High Voltage Transformers High Voltage Transformers typically these voltage transformers are used in power transmission applications. High voltage transformers are also used in microwave.
 

 Power Transformer Manufacturer

  • ACME Transformers - With Acme Electric being in business over 80 years, they have always believed in offering there customers superior service, quality and technical expertise in the transformer market.
  • AMVECO Transformers - AMVECO designs and manufactures toroids transformers, current transformers, and auto transformers. Most AMVECO products are custom designed utilizing their state-of-art proprietary CAD programs.  The AMVECO engineers can quickly generate designs in a matter of hours, if needed.
  • Federal Pacific TransformersFederal Pacific is a division of Electro- Mechanical Corporation, a privately held, American owned company founded in 1958. Federal pacific offers dry-type transformers from .050 KVA through 10,000 KVA single and three phase, up to 34.5 KV, 150 KV BIL with UL approval through 15 KV.
  • Marcus Transformer - Ever since they opened their doors for business a half a century ago, they have been a leader in innovative transformer design. As a family-owned company they are proud of the reputation they have earned for making quality-built transformers that deliver exceptional performance and savings.
  • Hammond TransformersHammond Manufacturing was founded in 1917 in Guelph, Ontario, Canada. In the last 3 decades it has expanded to the US and the international markets offering many types of power transformers. 
  • TEMCo Transformers - TEMCo Transformer, a family-owned business which has been manufacturing and distributing electrical products since 1968. They focus on transformers that significantly reduce power consumption over 30 percent compared to competitive makes.
  • GE Transformers - GE has been a key player in the energy industry for more than a century.  Since the installation of their first steam turbine in 1901. They have become number one provider of high-technology power generation and distribution equipment.
  • Jefferson Electric Transformers - Jefferson Electric has been a pioneer and innovator of magnetic products since 1915. Jefferson broad line of dry-type transformers are backed by quality assurance systems so stringent that each and every unit gets thoroughly tested before it goes out there door.
  • More power transformer brands - Check out more companies by clinking this link.

 Power Transformer Types

  • Distribution Transformers - Distribution transformers are generally used in electrical power distribution and transmission power. This class of transformer has the highest power, or volt-ampere ratings. and the highest continuous  voltage rating.
  • Substation Transformers - Substation Transformers are large devices which usually weigh tens of thousands of pounds.   They are filled with tens of thousands of gallons of heat transfer fluid.  Although they are typically 99.8% efficient in the transforming of electricity from one voltage to another, processing hundreds of Mega Volts-Amps of electricity force the liberation of hundreds of BTUs per second.
  • Medical Grade Isolation
     Transformer -
    Medical Grade Transformers generally refer to the transformers used in medical devices as well as hospital, biomedical and patient care equipment. There are a number of strict safety rules, guidelines and laws governing the design, construction and the test of these transformers.
  • Drive Isolation Transformer - They are used to isolate a drive from a main power line to prevent the transmission of harmonics that the drives produce back into the power line.  They stop drive harmonics from disrupting computers and other sensitive equipment.
  • Toroidal Transformers - Toroidal Transformers are more efficient than the cheaper laminated EI types of similar power level. Some of the advantages are smaller size, lower weight, less mechanical hum, (making them superior in audio amplifier), low-off-load loss.

 Power Transformer Types

  • Step-Up Transformers - A Step-Up Transformer is one whose secondary voltage is greater than its primary voltage.  This kind of transformer "steps up" the voltage applied to it. -
  • Step-Down Transformers - A Step-Down Transformer is  designed to reduce voltage from primary to secondary.  They can range from sizes from .05 KVA to 500 KVA
  • Isolation Transformers - An Isolation Transformer is a device that transfers energy from the alternating current (AC) supply to an electrical or electronic load.  It isolates the windings to prevent transmitting certain types of harmonics.
  • Buck Boost Transformers - Buck Boost Transformers make small adjustments to the incoming voltage. They are often used to change voltage from 208v to 240v for lighting applications.  Major advantages of Buck boost transformers include; low cost, compact size and light weight. 
  • High Voltage Transformer - There are many different types of voltage transformers. A High Voltage Transformer operates with high voltages. Typically, these voltage transformers are used in power transmission applications, where voltages are high enough to present a safety hazard.
  • Medium Voltage Transformers - A Medium Voltage Transformer can be connected directly to a primary distribution circuit and generally has the most load diversity. These voltage transformers have installation practices that are generally in accordance with application recommendations from the Institute of Electrical and Electronic Engineers (IEEE).
  • Low Voltage Transformers - A Low Voltage Transformer is an electrical device that transforms 120 volts (line voltage) into 12 volts or 24 volts (low voltage). Some uses for low voltage transformer are in landscaping lighting.
  • Single Phase Transformers - In electrical engineering, single-phase electric power refers to the distribution of electric power using a system in which all the voltages of the supply vary in unison. Single-phase distribution is used when loads are mostly lighting and heating, with few large electric motors.
  • Three Phase Transformers - Three Phase Transformers must have 3 coils or windings connected in the proper sequence in order to match the incoming power and therefore transform the power company voltage to the level of voltage needed while maintaining the proper phasing or polarity.
  • Custom Transformers - Custom Transformers are designed for a certain performance specifications and size requirements.  The company works with your engineering specification. 
  • Industrial Control Transformers - Industrial Control Transformers are used to convert the available supply voltage to the required voltage to supply industrial control circuits and motor control loads.
  • Pad Mounted Transformers - Pad Mounted Transformers are usually single phase, or three phase, and used where safety is a main concern. Typical applications; restaurant, commercial building, shopping mall, institutional. 
  • Pole Mounted Transformers - Pole Mounted Transformers are used for distribution in areas with overhead primary lines. Outside a typical house one can see one of these devices mounted on the top of an electrical pole.
  • Oil Filled Transformers - Oil Filled Transformers are transformers that use insulating oil as insulating materials.  The oil helps cool the transformer. Because it also provides part of the electrical insulation between internal live parts, transformer oil must remain stable at high temperatures over an extended period.
  • Dry Type Transformers - Dry-Type Transformers are available for voltages up through 34.5 kV (although the most common upper limit is 15) and KVA ratings up through 10,000 (with 5000 as the usual limit). Dry-type use air as a coolant, lowering health and environmentally concerns.
  • Auto Transformers - An Autotransformer is an electrical transformer with only one winding. The winding has at least three electrical connection points called taps. Autotransformers are frequently used in power applications to interconnect systems operating at different voltage classes, for example 138 kV to 66 kV for transmission. Another application is in industry to adapt machinery built for 480 V supplies to operate on the local 600 V supply.
  • More power transformer types - Read further about additional transformer types and their uses.

 Power Transformer Term Definitions

  • Electrical Transformers - Electrical Transformers are devices used to raise or lower the voltage of alternating current. For instance, power is transported over long distance in high voltage power lines and then transformers lower the voltage so that the power can be used by a business or household.
  • Isolating Transformers - An Isolating Transformer is a transformer, often with symmetrical windings, which is used to decouple two circuits.  An Isolation transformer allows an AC signal or power to be taken from one device and fed into another without electrically connecting the two circuits. Isolation transformers block transmission of DC signals from one circuit to the other, but allow AC signals to pass. 
  • Transmission Power Lines - A Transmission Line is the material medium or structure that forms all or part of a path from one place to another for directing the transmission of energy, such as electromagnetic or acoustic waves as well as electric power transmission. Components of transmission lines include wires, coaxial cables,  dielectric slabs, option fibers, electric power lines, and waveguides.
  • Transformer Voltage - The measure of the amount of force on a unit charge because of the surrounding charge.
  • Transformer Phase - Most transformer are either single phase or three phase.
  • Transformer Frequency - The transformer cannot change the frequency of the supply. If the supply is 60 hertz, the output will also be 60 hertz.
  • Transformer K Factor - Some transformers are now being offered with a k-factor rating. This measure the transformer's ability to withstand the heating effects of non-sinusoidal harmonic currents produced by much of today's electronic equipment and certain electrical equipment.
  • Primary Voltage - The coil winding that is directly connected to the input power.
  • Secondary Voltage - The coil winding  supplying the output voltage.
  • Harmonic Cancellation - Harmonic cancellation is performed with harmonic canceling transformers also known as phase-shifting transformers. A harmonic canceling transformer is a relatively new power quality product for mitigating harmonic problems in electrical distribution systems. This type of transformer has patented built-in electromagnetic technology designed to remove high neutral current and the most harmful harmonics from the 3rd through 21st.
  • Weatherproof - Enclosed transformers come with a weatherproof standard set by NEMA.
  • Epoxy Encapsulated - A process in which a transformer or one of its components is completely sealed with epoxy or a similar material. This process is normally preferred when a unit might encounter harsh environmental conditions.
  • More power transformer terms - Such as inductor, ground fault, core saturation, current transformer, faraday shield, etc.


Related Transformer Products

  • Voltage Regulators - A Voltage Regulator is an electrical regulator designed to automatically maintain a constant voltage level.  It may use an electromechanical mechanism, or passive or active electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.
  • AC Line Reactor - AC Line Reactors is a three phase transformer used in conjunction with AC variable frequency and DC motor drive. They are a bi-directional protective filtering device.
  • Line Power Conditioners - Power or Line Conditioners regulate, filter, and suppress noise in AC power for sensitive computer and other solid state equipment.
  • DC Power Supplies - Conversion of one form of electrical power to another desired form and voltage. This typically involves converting 120 or 240 volt AC supplied by a utility company to a well-regulated lower voltage DC for electronic devices.
  • Rotary Phase Converters - Rotary Phase Converters are commonly used in home or small commercial or industrial settings. Rotary phase converters convert single-phase power into three-phase power. This is a very cost-effective way to power three-phase electric motors and other three phase equipment.
  • Frequency Converters - A Frequency Changer or Frequency Converter is an electronic device that converts alternating current (AC) of one frequency to alternating current of another frequency.
  • Voltage Converters - A Voltage Converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply.
  • Magnetic Motor Starters - Magnetic Motor Starters are essentially heavy duty relays mounted in boxes, often equipped with heater/thermal overloads matched to the motor they start.
  • Motor Starting Auto Transformers - An Auto Transformer starter uses an auto transformer to reduce the voltage applied to a motor during start. The auto transformer may have a number of output taps and be set-up to provide a single stage starter, or a multistage starter.

For an additional resource the Best of Industry Web Directory : Electrical Power Transformer Directory section is quite useful.