|
|
Marcus Drive Isolation Transformers
To Order Marcus Transformers We Recommend TEMCo
Ph:
1-800-613-2290
Or 1-510-490-2187
Link:
Marcus Transformer |

THREE PHASE
Applications
For use with AC and DC adjustable speed drives which generate
mechanical stresses and harmonic currents beyond the design criteria of
normal general purpose transformers.
Features:
-
Heavy duty copper windings are firmly
braced to withstand mechanical stresses of drive operation.
-
Provide electrical isolation between primary line
and drive wiring.
-
Standard double electrostatic shielding between
input and output windings reduce problems
causing by line voltage transients.
-
In standard and special primary
temperature rise units for special applications.
-
Internal anti-vibration pads reduce
transmission of noise and vibration.
-
All terminals clearly labeled for
easy wiring
-
Interleaved winding and wound core
technology ensure excellent voltage regulation.
Sizing Selection
Know the motor horse power? Just follow the drive system
manufacturer's recommendations or select the corresponding kVA from the
chart below.
|
H.P. |
KVA |
| 5.0 |
7.5 |
| 7.5 |
11.0 |
| 10.0 |
14.0 |
| 15.0 |
20.0 |
| 20.0 |
27.0 |
| 25.0 |
34.0 |
|
30.0 |
40.0 |
| 40.0 |
51.0 |
| 50.0 |
63.0 |
| 60.0 |
75.0 |
| 75.0 |
93.0 |
| 93.0 |
118.0 |
| 125.0 |
145.0 |
| 150.0 |
175.0 |
| 200.0 |
220.0 |
| 250.0 |
275.0 |
| 300.0 |
330.0 |
| 400.0 |
440.0 |
| 500.0 |
550.0 |
| 600.0 |
660.0 |
.
Selection Charts
Class 220 degrees C, 150 degrees Rise,
60 Hz
|
Kva |
Catalog Number
600-240y/139
|
Catalog Number
480-480y/277 |
| 3 |
MDI 3A11 |
MDI 3B4 |
| 6 |
MDI 6A11 |
MDI 6B4 |
| 7.5 |
MDI 7.5A11 |
MDI 7.5B4 |
| 11 |
MDI 11A11 |
MDI 11B4 |
| 14 |
MDI 14A11 |
MDI 14B4 |
| 20 |
MDI 20A11 |
MDI 20B4 |
| 27 |
MDI 27A11 |
MDI 27B4 |
| 34 |
MDI 34A11 |
MDI 34B4 |
| 40 |
MDI 40A11 |
MDI 40B4 |
| 51 |
MDI 51A11 |
MDI 51B4 |
| 63 |
MDI 63A11 |
MDI 63B4 |
| 75 |
MDI 75A11 |
MDI 75B4 |
| 93 |
MDI 93A11 |
MDI 93B4 |
| 118 |
MDI 118A11 |
MDI 118B4 |
| 145 |
MDI 145A11 |
MDI 145B4 |
| 175 |
MDI 175A11 |
MDI 175B4 |
| 220 |
MDI 220A11 |
MDI 220B4 |
| 275 |
MDI 275A11 |
MDI 275B4 |
| 330 |
MDI 330A11 |
MDI 330B4 |
| 440 |
MDI 440A11
|
MDI 440B4 |
Class 220 degrees C, 150 degrees Rise,
60 Hz
|
Kva |
Catalog Number
480-240y/139
|
Catalog Number
240-240y/139 |
| 3 |
MDI 3B11 |
MDI 3G11 |
| 6 |
MDI 6B11 |
MDI 6G11 |
| 7.5 |
MDI 7.5B11 |
MDI 7.5G11 |
| 11 |
MDI 11B11 |
MDI 11G11 |
| 14 |
MDI 14B11 |
MDI 14G11 |
| 20 |
MDI 20B11 |
MDI 20G11 |
| 27 |
MDI 27B11 |
MDI 27G11 |
| 34 |
MDI 34B11 |
MDI 34G11 |
| 40 |
MDI 40B11 |
MDI 40G11 |
| 51 |
MDI 51B11 |
MDI 51G11 |
| 63 |
MDI 63B11 |
MDI 63G11 |
| 75 |
MDI 75B11 |
MDI 75G11 |
| 93 |
MDI 93B11 |
MDI 93G11 |
| 118 |
MDI 118B11 |
MDI 118G11 |
| 145 |
MDI 145B11 |
MDI 145G11 |
| 175 |
MDI 175B11 |
MDI 175G11 |
| 220 |
MDI 220B11 |
MDI 220G11 |
| 275 |
MDI 275B11 |
MDI 275G11 |
| 330 |
MDI 330B11 |
MDI 330G11 |
| 440 |
MDI 440B11 |
MDI 440G11 |
CHOOSING THE RIGHT TRANSFORMER
A transformer is a static piece of electrical equipment which
transfers power from one voltage system to another by means of
electromagnetic induction. The reason for using a transformer is to
match the voltage of the load to line voltage supplied by the utility.
TO SELECT THE RIGHT TRANSFORMER FOR YOUR SPECIFIC NEEDS,
DETERMINE THE FOLLOWING:
-
Primary voltage of transformer (available voltage).
-
Secondary voltage (voltage required for load
equipment).
-
Frequency (in Hz) and phases (normally single or
three phase).
-
kVA Load (add total number of pieces of equipment
involved). Consider possible future additions.
-
Is secondary voltage 2 wire or 3 wire ( single
phase) or 3 wire or 4 wire (three phase)?
-
Is double-wound or auto transformer required?
-
Is transformer to be floor or wall-mounted?
-
Is transformer for use indoors or outdoors?
OPTIONS
• Double electrostatic shielding is standard on all
Marcus drive isolation and K-Factor transformers and is also available
on all our distribution transformers
• Sprinkler shields are available on request
• All Marcus transformers operate quietly; if lower sound levels are
required, we can accommodate your needs
• Space limitations do not permit us to show every possible voltage. Ask
about special regional and custom voltages
• Special tap arrangements
• Anti-vibration pad kits (model AVP4)
Power Transformer Information:
|
 
Power Transformer Types
 |
Step Up and Step Down Transformers
to Power transformers to step-up ( raise) or step-down (lower) the
electrical voltage.
|
 |
Isolation Transformers
allows signal or power to be taken from one device and fed into
another without electrically connecting the two.
|
 |
Toroidal Transformers
are devices that transfer electrical energy from one electric
circuit to another, without changing the frequency, by
electromagnetic induction.
|

|
Custom
Transformers
are designed to meet certain performance specifications and size
requirement that you require. There is a wide range of custom
transformer types.
|

|
Buck Boost Transformers
is a ideal solution for changing line voltage by small amounts.
Often used to buck (lower), or boost (raise) the voltage from 208v
to 240v for lighting applications.
|

|
Pole Mounted Transformers
are mounted to poles for overhead electrical lines. Used in various applications.
Are available in single phase or three phase transformers.
|

|
Medium Voltage Transformers
are used with a medium range of voltages. They come in a full
range from liquid-filled, convention dry type as well as cast coil.
|
 |
Pad Mounted Transformers
are a excellent choice for commercial and industrial such as
manufacturing facilities, refineries, office buildings, schools,
hospitals, restaurants, and retail stores. They come in various
sizes and can be used underground as well.
|
 |
High
Voltage Transformers
typically these voltage transformers are used in power transmission
applications. High voltage transformers are also used in microwave.
|
|
- ACME Transformers
- With Acme Electric being in business
over 80 years, they have always believed in offering there customers superior service, quality and technical expertise in the
transformer market.
-
AMVECO Transformers -
AMVECO designs and manufactures toroids
transformers, current transformers, and auto transformers. Most
AMVECO products are custom designed utilizing their state-of-art proprietary
CAD programs. The AMVECO engineers can quickly generate designs in a
matter of hours, if needed.
-
Federal Pacific Transformers -
Federal Pacific is a division of Electro- Mechanical Corporation, a
privately held, American owned company founded in 1958. Federal
pacific offers dry-type transformers from .050 KVA through 10,000
KVA single and three phase, up to 34.5 KV, 150 KV BIL with UL
approval through 15 KV.
-
Marcus Transformer - Ever since they opened their doors for business a half a century ago,
they have been a leader in innovative transformer design. As a
family-owned company they are proud of the reputation they have
earned for making quality-built transformers that deliver
exceptional performance and savings.
-
Hammond Transformers - Hammond Manufacturing was founded in 1917 in Guelph, Ontario,
Canada. In the last 3 decades it has expanded to the US and the
international markets offering many types of power transformers.
- TEMCo Transformers
- TEMCo Transformer, a family-owned business which has been
manufacturing and distributing electrical products since
1968. They focus on transformers that significantly
reduce power consumption over 30 percent compared to competitive
makes.
- GE Transformers - GE has been a key player in the energy industry for
more than a century. Since the installation of
their first steam turbine in 1901. They have become
number one provider of high-technology power generation
and distribution equipment.
-
Jefferson Electric Transformers - Jefferson Electric has
been a pioneer and innovator of magnetic products since 1915.
Jefferson broad line of dry-type transformers are backed by quality
assurance systems so stringent that each and every unit gets
thoroughly tested before it goes out there door.
-
More power transformer brands -
Check out more companies by clinking this link.
Power Transformer Types
-
Distribution Transformers - Distribution
transformers are generally used in electrical power
distribution and transmission power. This class of transformer has
the highest power, or volt-ampere ratings. and the highest
continuous voltage rating.
-
Substation Transformers -
Substation Transformers are large
devices which usually weigh tens of thousands of pounds. They are
filled with tens of thousands of gallons of heat transfer fluid.
Although they are typically 99.8% efficient in the transforming of
electricity from one voltage to another, processing hundreds of Mega
Volts-Amps of electricity force the liberation of hundreds of BTUs
per second.
-
Medical Grade Isolation
Transformer -
Medical Grade Transformers generally refer to the transformers
used in medical devices as well as hospital, biomedical and patient
care equipment. There are a number of strict safety rules,
guidelines and laws governing the design, construction and the test
of these transformers.
-
Drive Isolation Transformer -
They are used to isolate a drive from a main power line to
prevent the transmission of harmonics that the drives produce back
into the power line. They stop drive harmonics from disrupting
computers and other sensitive equipment.
-
Toroidal Transformers -
Toroidal Transformers are more efficient than the cheaper laminated EI types of similar power level. Some of the advantages are smaller
size, lower weight, less mechanical hum, (making them superior in
audio amplifier), low-off-load loss.
|
-
Step-Up Transformers - A Step-Up Transformer is one whose
secondary voltage is greater than its primary voltage.
This kind of transformer "steps up" the voltage applied
to it. -
-
Step-Down Transformers
- A Step-Down Transformer is designed to reduce voltage from primary to
secondary.
They can range from sizes from .05 KVA to 500 KVA
-
Isolation Transformers -
An Isolation Transformer is a device that transfers energy from
the alternating current (AC) supply to an electrical or electronic
load. It isolates the windings to prevent transmitting certain
types of harmonics.
-
Buck Boost Transformers - Buck Boost
Transformers make small adjustments to the incoming voltage. They
are often used to change voltage from 208v to 240v for lighting
applications. Major advantages of Buck boost transformers
include; low cost, compact size and light weight.
-
High Voltage Transformer - There are many different types of
voltage transformers. A High Voltage Transformer operates with high
voltages. Typically, these voltage transformers are used in power
transmission applications, where voltages are high enough to present
a safety hazard.
-
Medium Voltage Transformers -
A Medium Voltage Transformer can be connected directly to a primary
distribution circuit and generally has the most load diversity.
These voltage transformers have installation practices that are
generally in accordance with application recommendations from the
Institute of Electrical and Electronic Engineers (IEEE).
-
Low Voltage Transformers
- A Low Voltage Transformer is an electrical device that transforms
120 volts (line voltage) into 12 volts or 24 volts (low voltage).
Some uses for low voltage transformer are in landscaping lighting.
-
Single Phase Transformers - In electrical engineering, single-phase electric power refers to the
distribution of electric power using a system in which all the
voltages of the supply vary in unison. Single-phase distribution is
used when loads are mostly lighting and heating, with few large
electric motors.
-
Three Phase Transformers - Three
Phase Transformers must have 3 coils or windings connected in
the proper sequence in order to match the incoming power and
therefore transform the power company voltage to the level of
voltage needed while maintaining the proper phasing or polarity.
-
Custom Transformers -
Custom Transformers are designed for a certain performance
specifications and size requirements. The company works with
your engineering specification.
-
Industrial Control Transformers -
Industrial Control Transformers are used to convert the
available supply voltage to the required voltage to supply
industrial control circuits and motor control loads.
-
Pad Mounted Transformers - Pad
Mounted Transformers are usually single phase, or three phase, and
used where safety is a main concern. Typical applications;
restaurant, commercial building, shopping mall, institutional.
-
Pole Mounted Transformers -
Pole Mounted Transformers are used for distribution in areas
with overhead primary lines. Outside a typical house one can see one
of these devices mounted on the top of an electrical pole.
-
Oil Filled Transformers -
Oil Filled Transformers are transformers that use insulating oil as
insulating materials. The oil helps cool the transformer.
Because it also provides part of the electrical insulation between
internal live parts, transformer oil must remain stable at high
temperatures over an extended period.
-
Dry Type Transformers - Dry-Type
Transformers are available for voltages up through 34.5 kV
(although the most common upper limit is 15) and KVA ratings up
through 10,000 (with 5000 as the usual limit). Dry-type use air as a
coolant, lowering health and environmentally concerns.
- Auto Transformers -
An Autotransformer is an electrical transformer with only one
winding. The winding has at least three electrical connection points
called taps. Autotransformers are frequently used in power
applications to interconnect systems operating at different voltage
classes, for example 138 kV to 66 kV for transmission. Another
application is in industry to adapt machinery built for 480 V
supplies to operate on the local 600 V supply.
- More power transformer types - Read further about additional
transformer types and their uses.
|
-
Electrical
Transformers -
Electrical Transformers are devices used to raise or lower the
voltage of alternating current. For instance, power is transported
over long distance in high voltage power lines and then transformers
lower the voltage so that the power can be used by a business or household.
-
Isolating
Transformers -
An Isolating Transformer is a transformer, often with
symmetrical windings, which is used to decouple two circuits.
An Isolation transformer allows an AC signal or power to be taken
from one device and fed into another without electrically connecting
the two circuits. Isolation transformers block transmission of DC
signals from one circuit to the other, but allow AC signals to pass.
-
Transmission
Power Lines - A Transmission Line is the material medium or structure that forms
all or part of a path from one place to another for directing the
transmission of energy, such as electromagnetic
or acoustic waves as well as electric power
transmission. Components of transmission lines include wires, coaxial
cables, dielectric slabs, option fibers,
electric power lines, and waveguides.
-
Transformer Voltage - The measure of the amount of force on a
unit charge because of the surrounding charge.
-
Transformer Phase - Most transformer are either single phase
or three phase.
-
Transformer Frequency -
The transformer cannot change the frequency of the supply. If the
supply is 60 hertz, the output will also be 60 hertz.
-
Transformer K Factor - Some transformers are now being offered
with a k-factor rating. This measure the transformer's ability to
withstand the heating effects of non-sinusoidal harmonic currents
produced by much of today's electronic equipment and certain
electrical equipment.
-
Primary Voltage - The coil winding that is directly connected
to the input power.
-
Secondary Voltage - The coil winding supplying the output
voltage.
-
Harmonic Cancellation -
Harmonic cancellation is performed with harmonic canceling
transformers also known as phase-shifting transformers. A harmonic
canceling transformer is a relatively new power quality product for
mitigating harmonic problems in electrical distribution systems.
This type of transformer has patented built-in electromagnetic
technology designed to remove high neutral current and the most
harmful harmonics from the 3rd through 21st.
- Weatherproof -
Enclosed transformers come with a weatherproof standard set by
NEMA.
- Epoxy Encapsulated -
A process in which a transformer or one of its components is
completely sealed with epoxy or a similar material. This process is
normally preferred when a unit might encounter harsh environmental
conditions.
-
More power transformer terms - Such as inductor, ground fault,
core saturation, current transformer, faraday shield, etc.
Related Transformer Products
-
Voltage Regulators - A
Voltage Regulator is an electrical regulator designed to
automatically maintain a constant voltage level.
It may use an electromechanical mechanism, or passive or active
electronic components. Depending on the design, it may be used to
regulate one or more AC or DC voltages.
-
AC Line Reactor -
AC Line Reactors is a three phase transformer used in
conjunction with AC variable frequency and DC motor drive.
They are a bi-directional protective filtering device.
-
Line Power Conditioners -
Power or Line Conditioners regulate, filter, and suppress noise in
AC power for sensitive computer and other solid state equipment.
-
DC Power Supplies -
Conversion of one form of electrical power to another desired
form and voltage. This typically involves converting 120 or 240 volt
AC supplied by a utility company to a well-regulated
lower voltage DC for electronic devices.
-
Rotary Phase Converters -
Rotary Phase Converters are commonly used in home or small
commercial or industrial settings. Rotary phase converters convert
single-phase power into three-phase power. This is a very
cost-effective way to power three-phase electric motors and other
three phase equipment.
-
Frequency Converters -
A Frequency Changer or Frequency Converter is an
electronic device that converts alternating current (AC) of one
frequency to alternating current of another frequency.
-
Voltage Converters -
A Voltage Converter changes the voltage of an electrical power
source and is usually combined with other components to create a
power supply.
-
Magnetic Motor Starters - Magnetic Motor Starters are
essentially heavy duty relays mounted in boxes, often equipped with
heater/thermal overloads matched to the motor they start.
-
Motor Starting Auto Transformers - An Auto
Transformer starter uses an auto transformer to reduce
the voltage applied to a motor during start. The auto transformer
may have a number of output taps and be set-up to provide a single
stage starter, or a multistage starter.
For an additional resource the
Best of Industry Web Directory
:
Electrical Power Transformer Directory section is quite useful. |
|